The ada home page provides access to americans with disabilities act ada regulations for businesses and state and local governments technical assistance materials ada standards for accessible design links to federal agencies with ada responsibilities and information updates on new ada requirements streaming video information about department of justice ada settlement agreements.
Ada exterior door clearance.
If you approach a door from the latch side and will need to pull the door open the minimum clearance on the opening side perpendicular to the doorway is 48 inches to allow for the door to open leaving room for a disabled individual to move.
All doors in alcoves shall comply with the clearances for front approaches.
Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door.
But in the case of pull side hinge side approaches greater latch side clearance 36 minimum is still required because the minimum depth for this.
The department of justice published revised regulations for titles ii and iii of the americans with disabilities act of 1990 ada in the federal register on september 15 2010.
On the parallel side beyond the latch is 24 inches should the door need to swing open.
404 2 4 1 swinging doors and gates.
Spring hinges door spring hinges shall be adjusted so that from the open position of 70 degrees the door shall.
Maneuvering clearances at doors.
Space at least 60 deep in front of a door that is unobstructed on approach sides will provide sufficient depth for a forward approach if appropriate strike side clearance is provided.
Minimum maneuvering clearances at doors and gates shall comply with 404 2 4.
Swinging doors and gates shall have maneuvering clearances complying with table 404 2 4 1.
Doors cannot swing into required clear floor or ground spaces in these specific instances.
Maneuvering clearances at doors.
Clear floor space at controls for automatic and power assisted doors and gates 404 3 5 fixture clearances in toilet and bathing facilities except those that are single user where wheelchair space beyond the door swing is provided 603 2 3.
Closing speed if a door is equipped with an automatic closing device.
However door maneuvering clearances can be offset up to 8 from the face of the door or gate to accommodate wall thickness casework shelves or other elements.
Maneuvering clearances shall extend the full width of the doorway and the required latch side or hinge side clearance.
No door maneuvering clearances must be free of any overlapping objects even those providing knee and toe clearance which can interfere with maneuvering at doors and doorways.
Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door.