This plan shows a typical example of a single user toilet room that meets the minimum requirements of the 1991 standards.
Ada restroom layout dimensions.
30 inch by 48 inch access to the sink the door can t swing into this rectangle.
Or for answers to.
An overview of ada bathroom layout requirements.
30 x 48 760 x 1220 mm of clear floor space is required in every restroom.
Restrooms fall into two major categories.
For single handicapped restrooms there must be a 60 diameter for a wheel chair in the room.
Grab bars must be installed between 34 and 38 inches above the floor and there must be a separation between the grab bar and the wall surface of at least 1 1 2 inches.
According to the 2010 update to adaag the basic ada guidelines for a single user restroom are.
5 0 x 7 3 36 25 square feet.
The grab bars are located off the back wall 33 36 from the floor and are 36 width.
Ada standards for accessible design can be downloaded from www ada.
Single door entries fig.
The measurement starts from the point where a person has 9 inch vertical clearance for their feet and 27 inch vertical clearance for their knees.
When 30 x 48 760 x 1220 mm clear floor space is provided beyond the arc of the door swing shaded area to right of door opening the door is permitted to swing into the clear.
1991 standards minimum with out swinging door.
Approximate room dimensions with a water closet and lavatory side by side the plumbing wall is typically determined by the width of the water closet clearance the lavatory fixture width plus any additional lavatory clearance beyond the fixture unless the lavatory is recessed.
Or for answers to specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383 tty.
The doorway must have a clear opening 32 inches 815mm minimum width when the door is open 90 degrees.
Another grab bar 42 length is also used at 33 36 from the floor off the wall on the side.
Comparison of single user toilet room layouts.
For more information for information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
For information about the ada including the revised 2010 ada regulations please visit the department s website www ada gov.
Specific questions call the toll free ada information line at 800 514 0301 voice or 800 514 0383.
An ada compliant grab bar handrail must be fully anchored and have a smooth surface that can be easily grabbed.
Private bathrooms like those found in residences and public restrooms.
The bar must be 1 1 4 to 1 1 2 inches in diameter.
A level and clear corridor or passageway leading to the door is recommended to be 48 inches 1220mm minimum wide.